High Pressure Scuba Diving Breathing Compressor

High Pressure Scuba Diving Breathing Compressor

High pressure scuba diving breathing compressor features fast fill speeds and quiet operation, perfect for busy dive centers.
Model: SLT-680
Working Pressure: 33 MPa (330 bar)
Displacement (Intake): 680 L/min
Type: X-configuration, 4-cylinder, 4-stage reciprocating piston compression
Drive: 380V/50Hz/15kW
Lubrication: Oil pump lubrication (Food-grade lubricant 750-H2)
Send Inquiry

High Pressure Scuba Diving Breathing Compressor

 

High pressure scuba diving breathing compressor features fast fill speeds and quiet operation, perfect for busy dive centers.

 

Model

SLT-680

Working Pressure

33 MPa (330 bar)

Displacement (Intake)

680 L/min

Type

X-configuration, 4-cylinder, 4-stage reciprocating piston compression

Drive

380V/50Hz/15kW

Lubrication

Oil pump lubrication (Food-grade lubricant 750-H2)

Cooling

Air-cooled

Control System

PLC system; features include automatic shutdown, automatic condensate drainage, temperature control, phase sequence protection, emergency stop, low noise/temperature/speed operation, oil filtration, and touchscreen display

Air Quality

Single-stage air filtration, 3-stage oil-water separation, single-stage air purification

Safety Features

Safety valves at all stages, automatic shutdown function, enclosed cabinet structure

Packaging Dimensions (L×W×H)

98×145×175 cm

Weight

680 kg

Filling Speed

Approx. 3 minutes to fill a 6-liter cylinder to 33 MPa

Certifications

CE certification, MA inspection report

 

Product Overview

 

This stationary high-pressure breathing air compressor is specifically designed for professional applications requiring stringent breathing air quality, such as firefighting, diving, oilfield operations, marine salvage, shooting training, and chemical processing. Engineered for high-intensity, continuous operation, the series combines automated functionality with customizable configuration options to easily meet air supply demands across diverse working conditions. Featuring a compact, vertically integrated layout, the unit offers a small footprint and high system integration; it is suitable for both fixed installations and mobile deployment, ensuring a reliable air supply for long-term, stable operations.

 

Key Advantages

 

01/

Multi-Stage Purification System

Features a tiered filtration and purification system-comprising intake filters, multi-stage oil-water separators, and activated carbon molecular filters-that effectively removes oil, water, dust, odors, and gaseous contaminants. This ensures the output air strictly meets EN12021 and GB/T31975-2015 breathing air quality standards, guaranteeing safety with every breath.

02/

Air-Cooled Design

Utilizes a high-efficiency air-cooling system that eliminates the need for external water cooling or additional cooling units. It effectively lowers unit and exhaust temperatures, ensuring stable operation in high-temperature or poorly ventilated environments while significantly reducing auxiliary maintenance costs.

03/

Durable Mechanical Structure

Employs a roller bearing design to significantly reduce friction loss in moving parts. Combined with a balanced crankshaft structure, it effectively minimizes operational vibration and enhances overall stability, thereby extending the service life of core components and lowering the total cost of ownership.

04/

Comprehensive Safety Protection

Equipped with a high-performance safety valve that automatically releases pressure during anomalies, eliminating over-pressure risks. Both electrical and mechanical systems feature overload and overheat protection, ensuring safe and reliable operation during unattended or automatic modes.

05/

Ultra-Quiet Operation

Optimized airflow paths, sound-insulating enclosures, and vibration-dampening designs keep operating noise below 70 dB(A)-significantly quieter than comparable products. This makes the unit ideal for noise-sensitive environments such as indoor fire stations and rescue command vehicles.

 

Intelligence and Customization

Automated Control System

The compressor features an integrated intelligent control system supporting one-touch start/stop, automatic pressure maintenance, automatic condensate drainage, and fault self-diagnosis with alarm alerts; this reduces the manual operational burden and enhances continuous operating efficiency.

Flexible Customization Solutions

For the stationary series, we offer modular customization services tailored to specific customer requirements regarding operating pressure, flow rate, discharge temperature, installation space, and filtration grade. Whether for gas cylinder filling stations, mobile gas supply vehicles, or centralized factory gas supply systems, we can craft the optimal solution for your needs.

 

Application Scenarios

 

  • Firefighting and Rescue: Rapidly refills air cylinders for breathing apparatus, ensuring a reliable air supply at fire and accident scenes.
  • Diving Operations: Supplies high-purity breathing air to deep-sea divers, ensuring safety during underwater operations.
  • Oilfields and Chemical Plants: Provides an independent, clean air source for personnel working in environments containing toxic or hazardous gases.
  • Salvage and Marine Operations: Meets the continuous demand for high-pressure air in maritime emergencies and underwater engineering projects.
  • Shooting Ranges: Supplies stable, dry, and clean high-pressure air for air guns and respiratory protection equipment.

SLT-680 Respirator Air Pump

 

Product Details

 

1
2
3

 

FAQ

 

Q1: What are the primary applications of the SLT-680 high-pressure breathing air compressor?

The SLT-680 high-pressure breathing air compressor is designed for professional scenarios requiring a supply of high-pressure, clean breathing air. Typical applications include:

  • Firefighting and Emergency Rescue: Deployed at fire station air supply depots or on fire vehicles, it enables on-site refilling of breathing air cylinders for firefighters during operations involving fires, heavy smoke, toxic gases, or chemical leaks, ensuring personnel safety.
  • Diving and Underwater Operations: Widely used in sectors such as diving clubs, offshore aquaculture, commercial fishing, maritime rescue, underwater engineering, salvage operations, shipbuilding, and water parks, providing divers with compressed breathing air that meets international standards.
  • Industrial and Mining Operations: Provides a safe and reliable air supply for personnel working in environments where oxygen deficiency or hazardous gases may be present, such as underground mining, tunnel construction, and chemical plant maintenance.
  • Other Emergency Rescue Operations: Can be used at the sites of natural disasters-such as earthquakes or floods-to provide breathing air support for rescue personnel.

Q2: What is the difference between a high-pressure breathing air compressor and a standard industrial air compressor?

Although both are air compression devices, there are fundamental differences in terms of design standards, output pressure, air quality, and safety requirements:

 

Comparison Item

High-pressure breathing air compressor (SLT-680)

Standard industrial air compressor

Operating pressure

High pressure: 33 MPa (330 bar)

Low pressure: Typically 0.8–1.6 MPa (8–16 bar)

Compression stages

Four-stage compression, progressive pressurization

Single-stage or two-stage compression

Air Quality

Multi-stage filtration and purification; complies with EN 12021 breathing air standards; oil-free and odorless.

Contains oil, moisture, and dust; unsuitable for breathing.

Material Requirements

Food-grade lubricant; non-toxic and odorless

Standard industrial lubricant; contains additives

Safety Standards

Multiple protective measures, including various safety valves, automatic shutdown, and temperature control protection

Typically features only overpressure protection and thermal protection

Application Scenarios

Breathing air (human use), firefighting, diving, rescue operations, etc.

Industrial applications such as pneumatic tools, spray painting, air purging, etc.

Q3: What safety protection measures are incorporated into the portable high-pressure breathing air compressor?

Although the SLT-680 is a cabinet-enclosed model, its safety protection system applies equally to both portable and stationary high-pressure breathing air compressors. Key safety measures include:

  • Pressure Safety Protection: Each compression stage is equipped with an independent safety valve that automatically releases pressure if the limit is exceeded; the system also features an automatic shutdown function that stops operation when the cylinder pressure reaches the preset value, preventing over-pressurization during filling.
  • Electrical Safety Protection: Includes multiple safeguards such as motor overload protection, over-voltage and under-voltage protection, phase sequence protection (to prevent motor reverse rotation), and star-delta soft starting (to reduce startup surge).
  • Temperature Safety Protection: An integrated temperature control system monitors exhaust temperature in real-time; it triggers an alarm and shuts down the unit if the temperature exceeds safe limits, preventing equipment damage or lubricant carbonization caused by high heat.
  • Emergency Shutdown Protection: A manual emergency stop button allows operators to instantly halt the machine and cut off operation upon detecting any abnormality.
  • Structural Safety Protection: The enclosed cabinet design prevents accidental contact with hot or moving parts while also providing sound insulation and noise reduction.
  • Automatic Condensate Drainage System: High-pressure condensate is automatically drained from the separators at timed intervals, preventing liquid accumulation that could cause liquid hammer damage to the compression chamber.

Q4: Does high-pressure breathing air compressor equipment require regular maintenance?

Yes. Regular maintenance is crucial for ensuring the equipment's long-term stable operation, extending its service life, and guaranteeing that the output air quality meets standards. The recommended maintenance schedule is as follows:

 

Maintenance Item

Frequency

Description

Oil Level Check

Before each use

Check the oil sight glass to ensure the lubricating oil level is within the normal range.

Air filter element

Every 300–500 hours of operation, or depending on ambient dust conditions

Filters intake air; clogging impairs intake efficiency and compression quality.

Inter-stage filter/oil-water separator filter element

Every ~500 hours of operation

Saturation or failure will impair oil-water separation performance and air quality.

Deep-purification filter cartridge

Every 500–1,000 hours of operation

Core component for final-stage breathing air purification; critical for respiratory safety

Lubricating Oil Change

First change after approximately 50 hours; subsequently every 500–1,000 hours

Use food-grade lubricating oil; do not mix with other types of oil.

Calibration of safety valves at all levels

At least once a year

Calibration by a professional agency to verify the accuracy of the opening pressure

Comprehensive inspection of the entire unit

Every 2,000 hours of operation or annually

Includes checking for wear on critical components such as piston rings, bearings, and coolers

Q5: What precautions should be taken when the equipment is not used for an extended period?

Before long-term shutdown (exceeding one month) and upon restarting, the following measures are recommended:

Preparation before shutdown:

  • Clean the exterior of the equipment to remove accumulated dust and oil stains.
  • Replace lubricating oil and filter elements that have been in service for a long time to prevent the old oil and filters from degrading or harboring bacteria during the shutdown period.
  • Drain condensate from all separators and pipelines to prevent accumulated water from corroding internal piping.
  • Store the equipment in a dry, well-ventilated, and dust-free indoor environment.
  • Cover the equipment with a dust cover to prevent dust from entering air intakes and crevices.
  • Disconnect the power supply and properly stow the power cord.

Checks before restarting:

  • Thoroughly inspect the power cord and electrical connections to ensure they are intact.
  • Check the oil level; top up or replace the lubricating oil if necessary.
  • Check for loose pipe connections and ensure the safety valve is in good condition.
  • Manually check that all drain valves operate smoothly.
  • Perform a brief low-pressure test run to monitor pressures, temperatures, and drainage; proceed to normal operation only after confirming there are no abnormalities.
  • If the equipment has been idle for more than six months, it is recommended to contact the manufacturer or a professional technician for a comprehensive inspection before restarting.

Q6: What are the practical benefits of the cabinet-style design?

The cabinet-style design not only gives the equipment a neat, attractive appearance but also offers multiple functions: first, sound insulation and noise reduction to minimize the outward spread of operating noise; second, dust protection to prevent external dust from entering moving parts; third, safety protection to prevent accidental contact with high-temperature or moving components; and fourth, ease of overall lifting and transport.

 

Hot Tags: high pressure scuba diving breathing compressor, China high pressure scuba diving breathing compressor manufacturers, suppliers, factory, high pressure breathing air compressor, high pressure breathing compressor, high pressure scuba diving air compressor, High Pressure Scuba Diving Breathing Compressor, mobile bauer breathing air compressors, Portable High Pressure Breathing Air Compressor

Looking for Premium, ReliableIndustrial Gas Compressors?

Explore Sollant's full range of compression equipment and elevate your operational efficiency! We ensure stable performance and reliable quality that fully meet rigorous industrial standards.
Contact us to customize your energy compression solution.

Send Inquiry